Santa Fe FWD L4-2.4L (2010)
Power Window Switch: Description and Operation
Operation
Function Of Safety Power Window
When all door (Front, Rear) power window auto-up switch is operated, safety function is activated.
1. Safety function condition
When detect the force of 100N during the window rising, window is reversed.
2. Length of window reversing (except holding the auto-up switch)
A. When detect the jamming during the 4mm ~ 250mm from top of the door.
-> Window is reversed until 300mm from top of the door.
B. When detect the jamming over the 250mm from top of the door.
-> Window is reversed until 50mm from jamming position.
-> Window is reversed 50mm or bottom position in case of 50mm reversing distance.
C. When detect the jamming over 300mm from top of the door.
-> Window stops at reverse point.
3. Length of window reversing (holding the auto-up switch)
A. When detect the jamming during holding the auto-up switch.
-> Window is reversed until 25mm from jamming position.
B. Auto-up function is not available during the 5 seconds from above condition.
-> When holding the auto-up switch, window is operated as a manual-up function. (Safety function is not activated.)
C. When detect the jamming during holding the auto-up switch again.
-> Window is reversed until 25mm from jamming position.
D. When holding the auto-up switch after 5 seconds from above condition.
-> Window is reverse until 25mm from jamming position.
4. Safety function is not available area
Safety function is not available during the 4mm from top of the door.
Initializing Method Of The Safety Power Window
1. Position counter and position initialization
(1) Position counter
Window position counting is implemented by use of one Hall Effect sensor (HEF) connected to timer capture unit of the Controller with a