Overdrive Solenoid: Testing and Inspection
Solenoid Valve

SOLENOID VALVE 

DESCRIPTION 

ACTUATORS 

Solenoid Valve for Pressure Control 

^

Sensor type: Normal open 3-way

^

Operating temperature: -30°C - 130°C (-22°F-266°F) 

^

Frequency: LR, 2ND, UD, OD: 61.27Hz (at the ATF temp. above -20°C (-4°F)) 
DCC: 30.64Hz 

^

Internal resistance:
3.0 ± 0.5 Ohms (LR, 2ND, UD, OD, TCC)
4.35 ± 0.5 Ohms (VFS)

^

Surge voltage: 56 V (Except VFS)

(LR, 2ND, UD, OD, DCC)