hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Body Control Module|Locations|Page 2308 > < Body Control Module|Locations|Page 2306
Page 2
background image

T1 : 0.3 ± 0.1s, T2 : more than 0.6s
T3 : 2.5 - 3.8s ± 0.1s, T4 : INT TIME-0.7s,
T5 : 0.2 - 0.6s, T6 : 0.7 ± 0.1s

2. MIST INTERLOCKING WIPER

(1) In IGN2 SW ON, if the MIST SW is ON for 60ms or more, within 100ms, and then, wiper output shall be ON for 700ms within 100ms.

T1 : Min 60 ms, T2 : Max 100 ms,
T3 : 700 ± 100 ms

(2) If MIST SW input is continued, WIPER output shall be maintain the ON state, and then if MIST SW is OFF, the Wiper output shall be ON for

700ms since OFF time.

T1 : Min 60 ms, T2 : Max 100 ms,
T3 : 700 ± 100 ms

(3) Mist SW input shall be disregarded by INT WIPER, WASHER interlocking WIPER during operating WIPER.

3. HEAD LAMP WASHER

(1) In the state that IGN2 SW is ON and HEADLAMP is ON, if the headlamp washer SW is ON, the headlamp washer relay shall be ON.
(2) After the operation by inputting the operation condition, the output shall be inhibited by disregarding the input condition occurred for 10

seconds.

T1 : 0.65 ± 0.1 sec,
T2 : 3.5 ± 0.1 sec,
T3 : 10 ± 1 sec.

4. VEHICLE SPEED (SENSITIVE TYPE) INT WIPER

According to the vehicle speed, control intermittent time of the Intermittent Wiper.
A. IGN1 SW ON state
B. WIPER SW INT state
C. INPUT the vehicle speed, intermittent time set VOLUME value

Body Control Module|Locations|Page 2308 > < Body Control Module|Locations|Page 2306