hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

EGR Valve Position Sensor > < EGR Temperature Sensor - Code 43 Diagnosis|Page 1425
Page 2
background image

3.

Heat the water to boiling, 100°C (212°F).

4.

Read the resistance value between terminals 1 and 2, resistance should be between 11-14 Kohm.

If the EGR Temperature Sensor measures out of the specification range, replace the sensor.