Neutral Safety Switch: Adjustments
Inhibitor Switch & Control Cable

Inhibitor Switch Adjustment Marks

1.

Place selector lever in Neutral position.

2.

Place manual control lever in Neutral position.

3.

Turn inhibitor switch body to align end of manual control lever with flange of inhibitor switch body.

4.

Torque inhibitor switch mounting bolts to 7-9 lb-ft.

Fig. 7 Adjusting Control Cable

5.

Loosen nut shown in Fig. 7, and lightly pull end of transaxle control cable in direction F. Torque nut to 7-10 lb-ft.

6.

Ensure selector lever is in Neutral position, and switch operates properly.