Sonata V6-2.7L (2004)
MANUAL UPDATE PROCEDURE:
NOTE:
In the event menu option "01. EF 2.7 03~05MY INTERMITTENT [AUTO]" fails to download the new program, option "02. EF 2.7 03~05MY
INTERMITTENT [ERROR]" must be used.
NOTE:
Confirm all connections are established as shown in the "AUTOMATIC UPDATE PROCEDURE" before continuing.
1.
Turn the ignition to the ON position.
2.
Turn the Hi-Scan Pro ON and press ENTER.
3.
Select option "47. EF 2.7 INTERMITTENT HESITATION" and press ENTER.
4.
Select option "02. EF 2.7 03~05MY INTERMITTENT [ERROR]" and press ENTER.
5.
Choose the vehicle type which is correct for your vehicle.