hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Purge Control Solenoid Valve (PCSV)|Page 5853 > < Diagram Information and Instructions|Page 5850
Page 1
background image

Canister Purge Solenoid: Testing and Inspection
Purge Control Solenoid Valve (PCSV)

PURGE CONTROL SOLENOID VALVE (PCSV)

DESCRIPTION

Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a
solenoid valve and is open when the PCM grounds the valve control line. When the passage is open (PCSV ON), fuel stored in the canister is transferred
to the intake manifold.

Specification

Schematic Diagram

Purge Control Solenoid Valve (PCSV)|Page 5853 > < Diagram Information and Instructions|Page 5850