hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Oxygen Sensor > < Diagram Information and Instructions|Page 4474
Page 1
background image

Manifold Pressure/Vacuum Sensor: Testing and Inspection

1. At idle, check the voltage using voltmeter.
2. It is important to make sure you are checking the correct pins.
3. Check to make sure the value is within specifications.

Standard value
at idle : 2.0 ± 0.3 V
 

CAUTION: Do not drop the MDP sensor. If it is dropped, don't reuse it.

CIRCUIT DIAGRAM

HARNESS INSPECTION