hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Oxygen Sensor- Operation/Diagnosis|Page 905 > < Oxygen Sensor- Operation/Diagnosis|Page 903
Page 4
background image

6.

Select "Digital Record" from the "Options" menu.

7.

Select CTRL and set ms/div to 30.00. Click "OK".

8.

Select "Run". Run the vehicle at 2500 rpm for several minutes, watch the signal. Record the signal after the engine has stabilized at 2500 rpm. The
front oxygen sensor signal should fluctuate quickly (Sonata from 0 to 1.0 V, Accent Elantra & Tiburon from 0.70 to 1.70 V).

9.

To view recorded data select 'Options" and 'Data Play Back" and the screen will show the analog form of the recorded data. To use the Digital
Overlay Feature during playback select "CTRL", "Playback", "Digital". Select "Zoom" and "-64" to change the scale to get the 1.92 Sec/Div
resolution.

Oxygen Sensor- Operation/Diagnosis|Page 905 > < Oxygen Sensor- Operation/Diagnosis|Page 903