hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Component Inspection|Page 4422 > < Component Inspection
Page 2
background image

1. Disconnect the vacuum hose (black with red stripe) from the solenoid valve.
2. Detach the harness connector.
3. Connect a vacuum pump to the nipple to which the red-striped vacuum hose was connected.

4. Apply vacuum and check when voltage is applied to the EVAP Canister Purge Solenoid Valve and when the voltage is discontinued.

5. Measure the current between the terminals of the solenoid valve.

EVAP Canister Purge Solenoid Valve:
Coil at 20°C (68°F) 0.45A or below (at 12V)
Coil resistance 26W [at 20°C (68°F)]

Vacuum Hose

Engine coolant temperature: 80 - 95°C (176 - 205°F)

1. Disconnect the vacuum hose from the intake manifold purge hose nipple and connect a hand vacuum pump to the nipple.