8. With the thermostatic switch connector in coupled state, install a voltmeter between 2 and 3 (-) terminal and check whether there is change in

voltage between terminals according to the temperature of the evaporator surface.

NOTE:  This check should be carried out on the back probes of the thermostatic switch when it is in coupled state.

9. If above condition is not satisfied, remove the evaporator unit and replace the thermostatic switch.

10. After inspection, install all the removal parts. Installation is the reverse order of removal.