Refrigerant Pressure Sensor / Switch: Description and Operation

TRIPLE PRESSURE SWITCH

DESCRIPTION

The triple switch is a combination of a medium switch as well as conventional low pressure and high pressure switches. The low pressure switch will turn
off to stop compressor operation if refrigerant pressure is low. The high pressure switch will turn off to stop compressor operation if refrigerant pressure
is too high. The medium switch will turn on at a medium level pressure to determine the A/C system is overheating. It will cool the A/C system by
operating the radiator fan and the condenser fan at high speed.

-

Rating load: Inductive load DC 12 V, 10-250 mA

-

Applicable voltage range: DC 8 V - DC 16 V

-

Applicable temperature range : -30 °C - 120 °C

-

Applicable refrigerant: R-134a

-

Insulation resistance: Min. 100 Mohms at DC 500 V

Operating characteristics (kg/sq.cm)

Relays and Modules - HVAC > < Diagram Information and Instructions|Page 9992