hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Inhibitor Switch|Page 7034 > < Inhibitor Switch|Page 7032
Page 1
background image

Transmission Position Switch/Sensor: Adjustments

TRANSAXLE RANGE SWITCH (INHIBITOR SWITCH)

ADJUSTMENT 

1. Set the select lever to the "N" position.
2. Loosen the control cable to manual control lever coupling nut to free the cable and lever.

3. Set the manual control lever to the neutral position.
4. Loosen the transaxle range switch body mounting bolts and then turn the transaxle range switch body so the hole in the end of the manual control

lever and the hole (cross section A-A in the figure) in the flange of the transaxle range switch body flange are aligned.

Tightening torque

5. Tighten the transaxle range switch body mounting bolts to the specified torque. Make sure at this time that the position of the switch body did not

move.
Tightening torque: 10 - 12 Nm (100 - 120 kg-cm, 7 - 8 ft. lbs.) 

6. Gently pull the transmission control cable in the direction of the arrow, and then tighten the adjusting nut.
7. Check that the select lever is in the RN position.

Inhibitor Switch|Page 7034 > < Inhibitor Switch|Page 7032