hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Blower Unit|Page 6821 > < Blower Unit|Page 6819
Page 3
background image

Repair Procedures

Replacement

1. Disconnect the negative (-) battery terminal.
2. Recover the refrigerant with a recovery/ recycling/ charging station.
3. When the engine is cool, drain the engine coolant from the radiator.
4. Remove the expansion valve cover (A).

5. Remove the bolts (A) and the expansion valve (B) from the evaporator core.

Plug or cap the lines immediately after disconnecting them to avoid moisture and dust contamination.

Tightening torque :
7.8 - 11.7 N.m ( 0.8 - 1.2 kgf.m, 5.7 - 8.6 lb-ft)

6. Disconnect the inlet (C) and outlet (D) heater hoses from the heater unit.

CAUTION:
Engine coolant will run out when the hoses are disconnected; drain it into a clean drip pan. Be sure not to let coolant spill on electrical parts or
painted surfaces. If any coolant spills, rinse it off immediately.

7. Remove the crash pad .
8. Disconnect the connectors from the temperature control actuator, the mode control actuator and the evaporator temperature sensor.
9. Remove the cowl cross bar assembly. 

10. Remove the heater & blower unit after loosening 3 mounting bolts.

Blower Unit|Page 6821 > < Blower Unit|Page 6819