hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Body Control Module|1 of 2|Page 3197 > < Body Control Module|1 of 2
Page 2
background image

T1 : 0.2s (MIN), T2 : 0.3s ± 0.1s, T3 : 2.5s ~ 3.8s (2 - 3 Turn), T4 : T5 - 0.7s, T5 : INT TIME, T6 : 0.06s ~ 0.2s, T7 : 0.7s ± 0.1s

(4) Operation is cancelled in case of IGN=OFF during T3.
(5) Give priority to Washer interlocking wiper than speed sensing INT wiper function.
(6) Washer switch signal input shall be ignored at start-up (IGN1 ON& IGN2 OFF states).
(7) Switch ON time includes chattering time.

2. MIST wiper control

(1) When turning on wiper mist switch with IGN2 ON, turning ON wiper low relay output for 700ms.

T1 : Min 60ms, T2: Max 100ms, T3 : 700±100ms

(2) If Wiper Mist switch input lasts for over 700ms, maintain Wiper low relay ON. IF Wiper Mist switch is OFF, turn ON Wiper low relay output

for 700ms from it is turned OFF.

T1 : Min 60ms, T2: Max 100ms, T3 : 700±100ms, T4 : 700ms

3. INT wiper control

(1) Intermittent time of intermittent wiper is controlled dependent on the following conditions.
(1) Wiper low relay time is 0.7s ±0.1s.
(2) Intermittent time is from output ON to the next output ON.
(3) Wiper low relay output is continued for remaining ON time if INT switch is turned OFF during output.
(4) Intermittent time is restarted when IGN2 switch is ON and Wiper INT switch is changed from OFF to ON.
(5) Intermittent time is restarted when Wiper INT switch is ON and IGN2 switch is changed from OFF to ON.
(6) 2.5V is used when VOLUME value is 2.5V or more.

Body Control Module|1 of 2|Page 3197 > < Body Control Module|1 of 2