hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Transmission Temperature Sensor/Switch, A/T|Service and Repair > < Diagram Information and Instructions|Page 4287
Page 1
background image

Transmission Temperature Sensor/Switch: Adjustments

Adjustment

TCM Learning

When shift shock is occurred or parts related with the transaxle are replaced, TCM learning should be performed.
In the following case, TCM learning is required.

-

Transaxle assembly replacement

-

TCM replacement

-

TCM upgrading

1. TCM learning condition

- ATF temperature: 60 - 115°C (140 - 239°F)

2. TCM learning procedure

A. Stop learning

Repeat the below shift pattern four times or more with stepping on the brake.

B. Driving learning

1. Drive the vehicle through all gears at D range. Drive from stop to 1st to 2nd to 3rd to 4th to 5th to 6th with keeping fixed throttle open.
2. Down shift from 6th to 5th, 5th to 4th, 4th to 3rd, 3rd to 2nd, 2nd to 1st.
3. Repeat the above driving pattern four times or more.

NOTE:

Up-shift throttle open : 15 - 30%