15. KEY LEARNING INTERNAL SOUND

Key Learning sound :
Frequency: 800 Hz
Sound period: 600msec
Sound duration: 600msec

When each Key's learning is ended, magnetic buzzer is operated, every one time.

16. KEY OPERATED WARNING

(1) KEY OPERATED WARNING SOUND

Frequency : 800 Hz
Sound period : T2 = 0.6sec
Sound duration : infinite

(2) KEY OPERATED WARNING ALGORITHM

A. (While IGN KEY is inserted into the KEY CYLINDER (*) Or ACC is ON) & (IGN1 = IGN2 = ALT'L = OFF) if DRIVER SIDE DOOR

is opened. KEY OPERATED WARN'G starts.
(*) if non SMK, or SMK option : KEY IN = TRUE

B. (If the KEY is pulled out from key cylinder & ACC = OFF)

Or IGN2 = ON
Or IGN1 = ON
Or ALT'L = ON
or if DRIVER SIDE DOOR is closed, then the key operated warning stops immediately.

C. DURATION: Permanent (The KEY OPERATED WARNING continues permanently if the condition has not changed)

NOTE:
-

The same definition is used for SMK and non SMK option.

-

The activation and deactivation must be made in the states. When an event with a higher priority interrupts the key reminder and when this
event finishes, the key reminder must be reactivated.

17. SMART KEY SYSTEM WARNINGS (SMART KEY OPTION ONLY)

(1) SMK(Smart Key) system warning sounds

In case of MAGNETIC BUZZER :
Frequency: 800 Hz
Sound period: T2 = 0.25 s
Number of period : 1
TON : 3 secs
TOFF : 0 secs