XG 350 V6-3.5L (2002)
Refrigerant Pressure Sensor / Switch: Description and Operation
TRIPLE PRESSURE SWITCH
The triple pressure switch is a combination of the low pressure switch (for checking the quantity of refrigerant) and the high pressure switch (for
prevention of overheating) and medium pressure switch (for operating cooling fan and condenser fan at high mode). It is installed in the receiver, and,
when the pressure becomes approximately 200 kPa (29 psi) or lower, the compressor stops, thus preventing the compressor from being damaged by
heat. When the pressure reaches 3,241 kPa (470 psi) or higher, the compressor stops, thus preventing overheating. There is generally no necessity for
inspection; if, however, an unusual condition, such as non-operation of the compressor is encountered, check by following the procedures.