infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

Additional Service When Removing Battery Negative Terminal|Page 4772 > < Additional Service When Removing Battery Negative Terminal|Page 4770
Page 2
background image

CALIBRATION PROCEDURE
1.AROUND VIEW MONITOR SCREEN CONFIRMATION
Check that there is the un-match display in any camera.

Is the un-match display visible?
YES - GO TO 2.
NO - GO TO 4.
2.CHECK THAT AROUND VIEW MONITOR CONTROL UNIT IS REPLACED
Check that the around view monitor control unit is replaced.
Is the around view monitor control unit replaced?
YES - GO TO 3.
NO - GO TO 5.
3.RELEASE UN-MATCH DISPLAY (PERFORM ONLY WHEN THE AROUND VIEW MONITOR CONTROL
UNIT IS REPLACED)
1. Select "Camera Cont." of Confirmation/ Adjustment mode, and then set to "Calibrating Camera Image" mode.

2. Press the "ENTER" switch of the multifunction switch on each screen of "Rear Camera", "Front Camera", "Dr-Side Camera", "Pass-Side

Camera".

CAUTION:
-

Do never operate the center dial and up/down/left/right switches. Only press the "ENTER" switch.

-

Never perform "Initialize Camera Image Calibration".

3. Display the around view monitor screen, and check that there is no malfunction such as a difference between each camera image.
Is there a malfunction?
YES - Calibration end
NO - GO TO 1.
4.PERFORM SIMPLIFIED CONFIRMATION/ADJUSTMENT BY "FINE TUNING OF BIRDS-EYE VIEW"
1. Put target line 1 on the ground beside each axle using packing tape, etc.
2. Put target lines 2 equal to the vehicle total length + approximately 1.0 m (39.3 in) from the vehicle side
(right and left) at approximately 30 cm (11.8 in) away from the vehicle (make the line as parallel with the vehicle as possible)
Preparation of simplified target line

Additional Service When Removing Battery Negative Terminal|Page 4772 > < Additional Service When Removing Battery Negative Terminal|Page 4770