POWER WINDOW DOWN FUNCTION DOES NOT OPERATE WITH KEY CYLINDER OPERATION

Diagnosis Procedure

1.CHECK DOOR KEY CYLINDER OPERATION
Check door key cylinder operation.
Does door lock/unlock with door key cylinder switch operation?
YES - GO TO 2.
NO - Go to See: Door Does Not Lock/Unlock With Door Key Cylinder Operation.
2.CHECK POWER WINDOW OPERATION
Check power window operation.
Does power window up/down with power window main switch?
YES - GO TO 3.
NO - Go to See: Windows and Glass/Windows/Testing and Inspection/Symptom Related Diagnostic Procedures/Power Windows Do Not Operate
With Any Power Window Switches.
3.CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES - Check intermittent incident. Refer to See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Intermittent Incident.
NO - GO TO 1.

Power Window Down Function Does Not Work When Operating With Intelligent Key

POWER WINDOW DOWN FUNCTION DOES NOT WORK WHEN OPERATING WITH INTELLIGENT KEY

Description

NOTE:
-

Before performing the diagnosis in the following procedure, check " Work Flow". Refer to See: Initial Inspection and Diagnostic
Overview/Diagnosis and Repair Work Flow.

POWER WINDOW DOWN FUNCTION DOES NOT WORK WHEN OPERATING WITH INTELLIGENT KEY

Diagnosis Procedure

1.CHECK REMOTE KEYLESS ENTRY FUNCTION
Check remote keyless entry function.
Does door lock/unlock with Intelligent key button?
YES - GO TO 2.
NO - Go to See: Door Does Not Lock/Unlock With Intelligent Key.
2.CHECK POWER WINDOW OPERATION
Check power window operation.
Does power window up/down with power window main switch?
YES - GO TO 3.
NO - Go to See: Windows and Glass/Windows/Testing and Inspection/Symptom Related Diagnostic Procedures/Power Windows Do Not Operate
With Any Power Window Switches.
3.CHECK "PW DOWN SET" SETTING IN "WORK SUPPORT"
Check "PW DOWN SET" setting in "WORK SUPPORT". Refer to See: Scan Tool Testing and Procedures/Intelligent Key.
Is the inspection result normal?
YES - GO TO 4.
NO - Set "PW DOWN SET" setting in "WORK SUPPORT".
4.CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES - Check intermittent incident. Refer to See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Intermittent Incident.
NO - GO TO 1.

Initial Inspection and Diagnostic Overview|Page 5398 > < Initial Inspection and Diagnostic Overview|Page 5396