7. Remove mounting bolt (A) and screw (B), from blower unit (1).
8. Remove blower unit.
CAUTION: Move blower unit rightward, and remove locating pin (1 part) and joint. Then remove blower unit downward.
INSTALLATION
Installation is basically the reverse order of removal.
CAUTION: Make sure locating pin (A) and joint (B) are securely inserted.