a. Using the tilt & telescope switch, run the telescope motor so the screw turns counterclockwise until it is completely out.
NOTE:
If the motor will not turn the telescope motor screw, it may be necessary to manually turn the screw using pliers or other hand tool.
b. Cut the tie-wrap.
c. Disconnect the electrical connector.
d. Use pliers to break the plastic electrical connector of the old motor so it will be unusable.
12. Remove the center support retaining nut (see Figure 19).
^ Use special tool J-49961 and 1/4" drive ratchet.
NOTE:
This is needed ONLY if the steering wheel could not be tilted to the full down position in step 1.