7. Remove low-pressure pipe (VK45DE).

INSTALLATION

Installation is basically the reverse order of removal.

CAUTION:

-

Replace O-rings for A/C piping with new one, then apply compressor oil to it when installing it.

-

Connection point for female-side piping is thin. So, when inserting male-side piping, take care not to deform female-side piping. Slowly insert in
axial direction.

-

Insert one-touch joint connection point securely until it clicks.

-

After piping has been connected, pull male-side piping by hand to check that piping does not come off.

-

When recharging refrigerant, check for leaks.

Bolt mounting the low-pressure flexible hose bracket
Tightening torque : 5.5 Nm (0.56 kg-m, 49 in-lb)

Removal and Installation of High-pressure Flexible Hose

REMOVAL

1. Use a refrigerant collecting equipment (for HFC-134a) to discharge the refrigerant.
2. Remove the air cleaner and air duct.

3. Remove mounting bolt for high-pressure flexible hose bracket.
4. Disconnect one-touch joint between high-pressure flexible hose and condenser.

a. Set a disconnector (92530-89912) on A/C piping.
b. Slide a disconnector upward until it clicks.

Hose/Line HVAC|Diagrams|Page 2306 > < Hose/Line HVAC|Diagrams|Page 2304