infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

Component Function Check|Page 5098 > < Component Function Check|Page 5096
Page 2
background image

YES  - GO TO 3.
NO - GO TO 6.
3.CHECK BLOWER MOTOR GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between blower motor harness connector and ground.

Is the inspection result normal?
YES  - GO TO 4.
NO - Repair harness or connector.
4.CHECK CIRCUIT CONTINUITY BETWEEN BLOWER MOTOR AND UNIFIED METER AND A/C AMP.
1. Disconnect unified meter and A/C amp. connector.
2. Check continuity between blower motor harness connector and unified meter and A/C amp. harness connector.

3. Check continuity between blower motor harness connector and ground.

Is the inspection result normal?
YES  - GO TO 5.
NO - Repair harness or connector.
5.CHECK UNIFIED METER AND A/C AMP. OUTPUT SIGNAL
1. Reconnect blower motor connector and unified meter and A/C amp. connector.
2. Turn ignition switch ON.
3. Set MODE switch to VENT position.
4. Change fan speed from Lo to Hi, and check duty ratios between blower motor harness connector and ground by using an oscilloscope. Normal

terminal 2 drive signal duty ratios are shown in the table below.

Is the inspection result normal?
YES  - Replace blower motor after confirming the fan air flow does not change.
NO - Replace unified meter and A/C amp.
6.CHECK POWER VOLTAGE OF BLOWER RELAY
1. Turn ignition switch OFF.
2. Remove blower relay.  See: Maintenance/Fuses and Circuit Breakers/Fuse Block/Diagrams.
3. Turn ignition switch ON.

Component Function Check|Page 5098 > < Component Function Check|Page 5096