FX35 RWD V6-3.5L (VQ35HR) (2010)
4. Check the voltage between blower relay fuse block terminals and ground. See: Power and Ground Distribution/Power Distribution
Relay/Description and Operation for relay terminal assignment.
Is the inspection result normal?
YES - GO TO 7.
NO - Check ignition power supply circuit. See: Diagrams/Electrical Diagrams/Power and Ground Distribution/System Diagram/Power Supply
Routing Circuit/Ignition Power Supply.
7.CHECK BLOWER RELAY
1. Turn ignition switch OFF.
2. Install blower relay. See: Maintenance/Fuses and Circuit Breakers/Fuse Block/Diagrams.
3. Check operation sound of the blower relay after switching ignition switch ON.
Is the inspection result normal?
YES - GO TO 8.
NO - Replace blower relay.
8.CHECK FUSE
Check fuse 15A [Nos. 21 and 22, located in the fuse block (J/B)]. See: Maintenance/Fuses and Circuit Breakers/Fuse Block/Diagrams.
Is the inspection result normal?
YES - Repair harness or connector.
NO - Be sure to eliminate cause of malfunction before installing new fuse.