Condenser HVAC > < Component Function Check|Page 5146
Page 2
background image

Is the inspection result normal?
YES  - · WITH CONSULT-III: GO TO 7.
-

WITHOUT CONSULT-III: Repair harness or connector.

NO -  See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Component Tests and General Diagnostics/Refrigerant
Pressure Sensor/Diagnosis Procedure (VQ35HR) or See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Component
Tests and General Diagnostics/Refrigerant Pressure Sensor/Diagnosis Procedure 
(VK50VE).
7.CHECK ECM INPUT SIGNAL-2
Check blower fan motor switch signal in "Data monitor".  See: Testing and Inspection/Scan Tool Testing and Procedures/Without
ACCS/CONSULT-III Function (WITHOUT ACCS) or See: Testing and Inspection/Scan Tool Testing and Procedures/With ACCS/CONSULT-III
Function (WITH ACCS).

FAN SWITCH ON : HEATER FAN SW On
FAN SWITCH OFF : HEATER FAN SW Off

Is the inspection result normal?
YES  - GO TO 8.
NO - Repair harness or connector.
8.CHECK CAN COMMUNICATION
Check CAN communication.  See: Powertrain Management/Computers and Control Systems/Information Bus/Testing and Inspection/Initial Inspection
and Diagnostic Overview/CAN Fundamental/Trouble Diagnosis Flow Chart.
-

ECM - IPDM E/R

-

ECM - Unified meter and A/C amp.

Is the inspection result normal?
YES  - Replace ECM.
NO - Repair or replace malfunctioning part(s).