infiniti Workshop Repair Guides

Infiniti FX45 AWD V8-45L Workshop Service and Repair Manuals

Door Sensor/Switch (For Alarm) > < Diagram Information and Instructions|Page 7555
Page 1
background image

Alarm Module: Diagnostic Aids

Ground Inspection

Ground connections are very important to the proper operation of electrical and electronic circuits. Ground connections are often exposed to moisture,
dirt and other corrosive elements. The corrosion (rust) can become an unwanted resistance. This unwanted resistance can change the way a circuit works.

Electronically controlled circuits are very sensitive to proper grounding. A loose or corroded ground can drastically affect an electronically controlled
circuit. A poor or corroded ground can easily affect the circuit. Even when the ground connection looks clean, there can be a thin film of rust on the
surface.

When inspecting a ground connection follow these rules:

-

Remove the ground bolt or screw.

-

Inspect all mating surfaces for tarnish, dirt, rust, etc.

-

Clean as required to assure good contact.

-

Reinstall bolt or screw securely.

-

Inspect for "add-on" accessories which may be interfering with the ground circuit.

-

If several wires are crimped into one ground eyelet terminal, check for proper crimps. Make sure all of the wires are clean, securely fastened and
providing a good ground path. If multiple wires are cased in one eyelet make sure no ground wires have excess wire insulation.

For detailed ground distribution information, refer to "Ground Distribution"

Door Sensor/Switch (For Alarm) > < Diagram Information and Instructions|Page 7555