Yaw Rate Sensor: Service and Repair
On-Vehicle Service

ON-VEHICLE SERVICE

Calibration of Decel G Sensor (AWD Models) 

NOTE:  After removing/installing or replacing yaw rate/side/decel G sensor, ABS actuator and electric unit (control unit), suspension components, or
after adjusting wheel alignment, make sure to calibration of decel G sensor before running vehicle. 

CAUTION:  To calibrate decel G sensor, make sure to use CONSULT-II. (Adjustment can not be done without CONSULT-II.)

1. Stop vehicle with front wheels in straight-ahead position. 

CAUTION:  
^

The work should be done at a horizontal place when vehicle is in the unloaded vehicle condition. 

^

Keep all tires inflated to correct pressures. Adjust the tire pressure to the specified pressure value. 

2. Perform CONSULT-II Starting Procedure. Refer to GI-38, CONSULT-II Start Procedure. See: Testing and Inspection/Reading and Clearing

Diagnostic Trouble Codes

3. Touch ABS, WORK SUPPORT and DECEL G-SEN CALIBRATION on CONSULT-II screen in this order. 

4. Touch START.

CAUTION:  Set vehicle as shown in the display. 

5. After approximately 10 seconds, touch END. (After approximately 60 seconds, it ends automatically)
6. Turn ignition switch OFF, then turn it ON again. 

CAUTION:  Be sure to perform above operation. 

7. Run vehicle with front wheels in straight-ahead position, then stop. 
8. Select DATA MONITOR, SELECTION FROM MENU, and DECEL G-SEN on CONSULT-II screen. Then make sure DECEL G-SEN is within 

0 ± 0.08 G. If value is more than specification, repeat steps 3 to 7. 

9. Erase memory of ABS actuator and electric unit (control unit) and ECM. 

10. Turn ignition switch OFF. 