CAUTION: Turn the screw slowly. The value change on display is slower than actual movement of the ICC sensor. Wait for 2 seconds every
time the screw is turned half a rotation.
NOTE: Turning the screw to the right lowers the aiming and to the left lifts the aiming.
5. When "U/D CORRECT" value indicates ±4, confirm that the margin of value remains within - 4 at least for 2 seconds with no equipment or hand
touching the ICC sensor.
When "COMPLETED THE VERTICAL AIMING OF LASER BEAM" appears on screen, touch "END".
CAUTION: Be sure that the margin of "U/D CORRECT" is within +/- 4 with ICC sensor unit is untouched.
6. Confirm that "ADJUSTING AUTOMATIC HORIZONTAL LASER BEAM AIMING" is on screen and wait for a while (maximum: 10 seconds).
7. Confirm that "NORMALLY COMPLETED" is displayed on CONSULT-II and close the aiming adjustment procedure by touching "END".
CAUTION: Complete all the procedures once "LASER BEAM ADJUST" mode is entered in CONSULT-II. When the procedure is
discontinued, the ICC system is inoperable.
CHECK AFTER THE ADJUSTMENT
Test the ICC system operation by running test. Refer to "ICC System Running Test".