FX50 AWD V8-5.0L (VK50VE) (2009)
Shift Indicator: Description and Operation
System Description
METER SYSTEM
SHIFT POSITION INDICATOR : System Description
Shift position is displayed in the information display LCD in the combination meter.
MANUAL MODE
When operated with selector lever
-
Unified meter and A/C amp. inputs manual mode signal and manual mode shift-up/down signal from control device (manual mode switch), and
transmits the signals to TCM with CAN communication line.
-
TCM processes manual mode signal and manual mode shift-up/down signal, and transmits manual mode indicator signal and shift position signal
to unified meter and A/C amp. with CAN communication line.
-
Unified meter and A/C amp. transmits manual mode indicator signal and shift position signal to combination meter with the communication line.
-
Combination meter indicates A/T gear position and manual mode indicator, when receiving manual mode indicator signal and shift position signal.
When operated with paddle shifter
-
Unified meter and A/C amp. inputs manual mode signal from control device (manual mode switch) or the paddle shifter-up/down signal from the
paddle shifter.
-
Unified meter and A/C amp. transmits manual mode signal and manual mode shift-up/down signal to TCM with the CAN communication line.
-
TCM processes manual mode signal and manual mode shift-up/down signal, and transmits manual mode indicator signal and shift position signal
to unified meter and A/C amp. with CAN communication line.
-
Unified meter and A/C amp. transmits manual mode indicator signal and shift position signal to combination meter with the communication line.
-
Combination meter indicates A/T gear position and manual mode indicator, when receiving manual mode indicator signal and shift position signal.
NOT MANUAL MODE
-
Unified meter and A/C amp. inputs not manual mode signal from control device (manual mode switch), and transmits the signals to TCM with
CAN communication line.
-
TCM transmits shift position signal to unified meter and A/C amp. with CAN communication line.
-
Unified meter and A/C amp. transmits shift position signal to combination meter with the communication line.
-
Combination meter indicates shift position when receiving shift position signal.