infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2431 > < Initial Inspection and Diagnostic Overview|Page 2429
Page 6
background image

Is the inspection result normal?
YES - GO TO 3.
NO - Check the harness and repair the root cause.
3.CHECK HARNESS CONTINUITY (SHORT CIRCUIT)
Check the continuity between the data link connector and the ground.

Is the inspection result normal?
YES - GO TO 4.
NO - Check the harness and repair the root cause.
4.CHECK CAN GATEWAY TERMINATION CIRCUIT
1. Remove the CAN gateway.

2. Check the resistance between the CAN gateway terminals.

Is the measurement value within the specification?
YES - GO TO 5.
NO - Replace the CAN gateway.
5.CHECK SYMPTOM
Connect all the connectors. Check if the symptoms described in the "Symptom (Results from interview with customer)" are reproduced.
Inspection result
Reproduced-GO TO 6.
Non-reproduced-Start the diagnosis again. Follow the trouble diagnosis procedure when past error is detected.
6.CHECK UNIT REPRODUCTION
Perform the reproduction test as per the following procedure for each unit.
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Disconnect one of the unit connectors of CAN communication circuit 2.

NOTE:
CAN gateway have a termination circuit. Check other units first.
4. Connect the battery cable to the negative terminal. Check if the symptoms described in the "Symptom
(Results from interview with customer)" are reproduced.

NOTE:
Although unit-related error symptoms occur, do not confuse them with other symptoms.

Initial Inspection and Diagnostic Overview|Page 2431 > < Initial Inspection and Diagnostic Overview|Page 2429