Fluid - Transfer Case: Service and Repair
Refilling

TRANSFER FLUID

VK50VE : Refilling

1. Remove filler plug (1) and gasket. Then fill fluid up to mounting hole for the filler plug.

Fluid and viscosity : Refer to "Fluids and Lubricants". See: Maintenance
Fluid capacity : Refer to "General Specifications". See: Specifications/Mechanical Specifications

CAUTION:
Carefully fill the fluid. (Fill up for approximately 3 minutes.)
2. Leave the vehicle for 3 minutes, and check the fluid level again.
3. Set a new gasket onto filler plug, and install it on transfer and tighten to the specified torque. 

CAUTION:
Never reuse gasket.