G20 L4-2.0L (SR20DE) (1992)
Air Regulator: Testing and Inspection
1.
Disconnect regulator harness connector.
2.
Check resistance between air regulator connector. Resistance should be approximately 70 - 80 ohms.
3.
Check air regulator for clogging.