G35 Sedan V6-3.5L (VQ35HR) (2008)
1. Clean piping connection point, and set a disconnector.
2. Slide disconnector in axial direction of piping, and stretch garter spring with tapered point of disconnector.
3. Slide disconnector farther so that inside diameter of garter spring becomes larger than outside diameter of female-side piping flare. Then male-side
piping can be disconnected.
INSTALLATION
1. Clean piping connection points, and insert male-side piping into female-side piping.
2. Push inserted male-side piping harder so that female-side piping flare stretches garter spring.
3. Garter spring seats on flare if inside diameter of garter spring becomes larger than outside diameter of female-side piping flare. Then, it fits in
between male-side piping cage and female-side piping flare to anchor piping connection point.
NOTE: When garter spring seats on flare, and fits in between male-side piping cage and female-side piping flare, it clicks.
CAUTION:
-
Female-side piping connection point is thin and easy to deform. Slowly insert the male-side piping straight in axial direction.
-
Insert piping securely until a click is heard.
-
After piping connection is completed, pull male-side piping by hand to make sure that connection does not come loose.
NOTE: One-touch joint connection is used in points below.
-
Low-pressure flexible hose to low-pressure pipe 2 (O-ring size: 16)
-
Low-pressure pipe 1 to low-pressure pipe 2 (O-ring size: 16)
-
High-pressure flexible hose to condenser pipe assembly (O-ring size: 12)
-
High-pressure pipe 1 to high-pressure pipe 2 (O-ring size: 8)
-
High-pressure pipe 1 to condenser pipe assembly (O-ring size: 8)
O-RING AND REFRIGERANT CONNECTION