infiniti Workshop Repair Guides

Infiniti G35 Sedan V6-35L Workshop Service and Repair Manuals

Heating and Air Conditioning System|Page 4965 > < Heating and Air Conditioning System|Page 4963
Page 3
background image

Refrigerant Connection

A new type refrigerant connection has been introduced to all refrigerant lines except the following location.

-

Expansion valve to evaporator

-

Refrigerant pressure sensor to liquid tank

ABOUT ONE-TOUCH JOINT

Description

-

One-touch joints are pipe joints which do not require tools during piping connection.

-

Unlike conventional connection methods using union nuts and flanges, controlling tightening torque at connection point is not necessary.

-

Use a disconnector when removing a pipe joint.

COMPONENT PARTS

FUNCTIONS OF COMPONENT PARTS

NOTE:

-

Garter spring cannot be removed from cage of male-side piping.

-

Indicator ring remains near piping connection point, however, this is not a malfunction. (This is to check piping connection during factory
assembly.)

REMOVAL

Heating and Air Conditioning System|Page 4965 > < Heating and Air Conditioning System|Page 4963