Tire Pressure Sensor Reset Procedure
Without Transmitter Activation Tool
ID REGISTRATION WITHOUT ACTIVATION TOOL
This procedure must be done after replacement of a transmitter or BCM.
CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunction might be detected during self diagnosis
depending on control unit which performs CAN communication.
1. With the ignition switch OFF, connect CONSULT-II and CONSULT-II CONVERTER to the data link connector, then turn the ignition switch
ON.
2. Select START (NISSAN BASED VHCL).
3. Select BCM on SELECT SYSTEM screen.
NOTE: If BCM is not indicated, go to GI-38, "CONSULT-II Data Link Connector (DLC) Circuit." See: Diagrams/Electrical
Diagrams/Powertrain Management/Data Link Connector/Data Link Connector Schematic
4. Select AIR PRESSURE MONITOR on SELECT WORK ITEM screen.
5. Select WORK SUPPORT on SELECT DIAG MODE screen, and select ID REGIST.
6. Adjust the tire pressure to the values shown in the table for ID registration, and drive the vehicle at 40 km/h (25 MPH) or more for a few
minutes.
7. After completing all ID registrations, press END to complete the procedure.
8. Inflate all tires to proper pressure. Refer to SERVICE DATA AND SPECIFICATIONS (SDS).
With Transmitter Activation Tool
ID REGISTRATION WITH ACTIVATION TOOL
This procedure must be done after replacement of a transmitter or BCM.
CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunction might be detected during self diagnosis
depending on control unit which performs CAN communication.
1. With the ignition switch OFF, connect CONSULT-II and CONSULT-II CONVERTER to the data link connector, then turn the ignition switch
ON.
2. Select START (NISSAN BASED VHCL).
3. Select BCM on SELECT SYSTEM screen.
NOTE: If BCM is not indicated, go to GI-38, CONSULT-II Data Link Connector (DLC) Circuit. See: Diagrams/Electrical Diagrams/Powertrain
Management/Data Link Connector/Data Link Connector Schematic
4. Select AIR PRESSURE MONITOR on SELECT WORK ITEM screen.
5. Select WORK SUPPORT on SELECT DIAG MODE screen, and select ID REGIST.