infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

Low-Pressure Flexible Hose and Pipe 2|Page 6508 > < Low-Pressure Flexible Hose and Pipe 2|Page 6506
Page 1
background image

Hose/Line HVAC: Service and Repair
Low-Pressure Pipe 1 and High-Pressure Pipe 2

LOW-PRESSURE PIPE 1 AND HIGH-PRESSURE PIPE 2

Exploded View HA-51

Exploded View

Refer to "Refrigerant Connection".

Removal and Installation

REMOVAL

1. Set the temperature at 18 °C (60 °F), and then disconnect the battery cable from the negative terminal.
2. Use a refrigerant collecting equipment (for HFC-134a) to discharge the refrigerant.
3. Remove cowl top cover.

4. Disconnect the one-touch joint between low-pressure pipe 1 (1) and low-pressure pipe 2 (2) with disconnector (A) (SST: 9253089916).

Low-Pressure Flexible Hose and Pipe 2|Page 6508 > < Low-Pressure Flexible Hose and Pipe 2|Page 6506