G37x Sedan AWD V6-3.7L (VQ37VHR) (2010)
Blower Motor: Testing and Inspection
Component Function Check
BLOWER MOTOR
Component Function Check
1.CONFIRM SYMPTOM BY PERFORMING THE FOLLOWING OPERATIONAL CHECK
1. Press fan (UP: +) switch*1 (turn fan control dial clockwise*2). Blower should operate on low speed.
NOTE:
*1: With left and right ventilation temperature separately control system.
*2: Without left and right ventilation temperature separately control system.
2. Press fan (UP: +) switch*1 (turn control dial clockwise*2), and continue checking fan speed and fan symbol until all speeds checked.
NOTE:
*1: With left and right ventilation temperature separately control system.
*2: Without left and right ventilation temperature separately control system.
Is the inspection result normal?
YES - INSPECTION END
NO - Go to diagnosis procedure. Refer to See: Testing and Inspection/Component Tests and General Diagnostics/Blower Motor/Diagnosis Procedure.