YES - GO TO 2.
NO - Repair the terminal and connector.
2.CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect the connector of pre-crash seat belt control unit.
2. Check the resistance between the pre-crash seat belt control unit harness connector terminals.

Is the measurement value within the specification?
YES - GO TO 3.
NO - Repair the pre-crash seat belt control unit branch line.
3.CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the pre-crash seat belt control unit. Refer to See: Restraint Systems/Seat Belt Systems/Testing and
Inspection/Component Tests and General Diagnostics/Power Supply and Ground Circuit.
Is the inspection result normal?
YES (Present error)-Replace the pre-crash seat belt control unit. Refer to See: Relays and Modules/Relays and Modules - Restraint Systems/Seat Belt
Control Module/Service and Repair/Exploded View.
YES (Past error)-Error was detected in the pre-crash seat belt control unit branch line.
NO - Repair the power supply and the ground circuit.

CAN

M&#38;A BRANCH LINE CIRCUIT

Diagnosis Procedure

1.CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Check the terminals and connectors of the unified meter and A/C amp. for damage, bend and loose connection (unit side and connector side).
Is the inspection result normal?
YES - GO TO 2.
NO - Repair the terminal and connector.
2.CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect the connector of unified meter and A/C amp.
2. Check the resistance between the unified meter and A/C amp. harness connector terminals.

Is the measurement value within the specification?
YES - GO TO 3.
NO - Repair the unified meter and A/C amp. branch line.
3.CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the unified meter and A/C amp. Refer to See: Instrument Panel, Gauges and Warning
Indicators/Testing and Inspection/Component Tests and General Diagnostics/Power Supply and Ground Circuit/Unified Meter and A/C Amp.,
"UNIFIED METER AND A/C AMP. : Diagnosis Procedure".
Is the inspection result normal?
YES (Present error)-Replace the unified meter and A/C amp. Refer to See: Instrument Panel, Gauges and Warning Indicators/Service and
Repair/Unified Meter and A/C Amp./Exploded View.
YES (Past error)-Error was detected in the unified meter and A/C amp. branch line.
NO - Repair the power supply and the ground circuit.

CAN System (Type 1)

M&#38;A BRANCH LINE CIRCUIT

Diagnosis Procedure

1.CHECK CONNECTOR
1. Turn the ignition switch OFF.

Initial Inspection and Diagnostic Overview|Page 2443 > < Initial Inspection and Diagnostic Overview|Page 2441