Refueling Vapor Recovery System: Testing and Inspection
Component Inspection

ON BOARD REFUELING VAPOR RECOVERY (ORVR)

Component Inspection

1.INSPECTION START
Do you have CONSULT-III?
Do you have CONSULT-III?
YES - GO TO 2.
NO - GO TO 3.
2.CHECK REFUELING EVAP VAPOR CUT VALVE
With CONSULT-III
1. Turn ignition switch OFF.
2. Remove fuel tank. Refer to See: Fuel Delivery and Air Induction/Fuel Tank/Service and Repair/Removal and Installation.
3. Drain fuel from the tank as follows:
- Remove fuel feed hose located on the fuel gauge retainer.
- Connect a spare fuel hose, one side to fuel gauge retainer where the hose was removed and the other side to a fuel container.
- Drain fuel using "FUEL PUMP RELAY" in "ACTIVE TEST" mode with CONSULT-III.
4. Check refueling EVAP vapor cut valve for being stuck to close as follows.
Blow air into the refueling EVAP vapor cut valve (from the end of EVAP/ORVR line hose), and check that the air flows freely into the tank.
5. Check refueling EVAP vapor cut valve for being stuck to open as follows.
- Connect vacuum pump to hose end.
- Remove fuel gauge retainer with fuel gauge unit.
Always replace O-ring with new one.
- Turn fuel tank upside down.
Apply vacuum pressure to hose end [-13.3 kPa (-0.136 kg/cm3, -1.93 psi)] with fuel gauge retainer remaining open and check that the pressure is
applicable.

Is the inspection result normal?
YES - INSPECTION END
NO - Replace refueling EVAP vapor cut valve with fuel tank.
3.CHECK REFUELING EVAP VAPOR CUT VALVE
Without CONSULT-III
1. Turn ignition switch OFF.
2. Remove fuel tank. Refer to See: Fuel Delivery and Air Induction/Fuel Tank/Service and Repair/Removal and Installation.
3. Drain fuel from the tank as follows:
- Remove fuel gauge retainer.
- Drain fuel from the tank using a handy pump into a fuel container.
4. Check refueling EVAP vapor cut valve for being stuck to close as follows.
Blow air into the refueling EVAP vapor cut valve (from the end of EVAP/ORVR line hose), and check that the air flows freely into the tank.
5. Check refueling EVAP vapor cut valve for being stuck to open as follows.
- Connect vacuum pump to hose end.
- Remove fuel gauge retainer with fuel gauge unit.
Always replace O-ring with new one.
- Turn fuel tank upside down.

Diagnosis Procedure|Page 2793 > < Diagnosis Procedure|Page 2791