Special Tool - A/C Leak Detector

Reference:
ITB98-029

Classification:
TE98-002

Date:
July 15, 1998

NEW A/C LEAK DETECTOR

APPLIED VEHICLES: 
All with air conditioning

SERVICE INFORMATION

A new A/C leak detector (Leybold Inficon D-TEK, tool number J41995) for R12 and R134a has been released as a dealer replacement for the Yokogawa
J39400 leak detector (see Figure 1). While both units are approved by Nissan Motor Corporation for use, the operation, portability and
response/recovery time of the D-TEK is improved over the Yokagawa unit. Use of the Yokogawa J39400 is still approved, however all replacements
should be the D-TEK unit.

The simple calibration of the D-TEK combined with the following service procedure should reduce diagnostic time.

SERVICE PROCEDURE

1.

Read all manufacture's operating and maintenance instructions before using the Inficon D-TEK for the first time.

2.

Make sure the vehicle's A/C system has a minimum pressure of 50 psi.

3.

Visually inspect the D-TEK's probe tip filter for contamination before use. Clean or replace the probe tip filter as needed.

4.

Place the sensitivity selector in the HI position and move the power switch to the ON position. Check the unit for the following conditions:

^

The green lamp should be steady (not flashing) indicating the power cells are fully charged. If the green lamp is dim, out, or flashing,
connect the power supply cord and charge the power cells.

NOTE: The D-TEK can be operated while the power cells are re-charging, however this will lengthen the time required for a complete
charge.

^

The alarm should sound and the seven yellow lamps will light for 15 to 20 seconds during warm-up. When the warm up is complete, the
alarm and yellow lamps will go off. The D-TEK is now ready to be calibrated.

NOTE: If the green lamp is not steady, or if there are any improper warm up conditions, refer to the operator's manual for trouble shooting
procedures.