J30 V6-2960cc 3.0L DOHC (VG30DE) (1995)
Checking Electrolyte Level
Electrolyte Level
WARNING: Do not allow Battery fluid to come In contact with skin, eyes, fabrics, or painted surfaces. After touching a Battery, do not touch
or rub your eyes until you have thoroughly washed your hands. If the acid contacts the eyes, skin or clothing, Immediately flush with water for
15 minutes and seek medical attention.
Normally the battery does not require additional water. However, when the battery is used under severe conditions, adding distilled water may be
necessary during the battery life.
Remove the cell plug using a suitable tool.
Add distilled water up to the MAX level.
Specific Gravity Check
Prevention Of Over-Discharge
1. Read hydrometer and thermometer indications at eye level.
Specific Gravity Check
^ When electrolyte level is too low, tilt battery case to raise it for easy measurement.