J30 V6-2960cc 3.0L DOHC (VG30DE) (1995)
Neutral Safety Switch: Adjustments
1. Remove control cable end from manual shaft, then set manual shaft in "N" range.
2. Loosen inhibitor switch attaching bolts, then insert a 0.157 inch diameter pin into adjustment holes on both inhibitor switch and manual shaft as
near vertical as possible.
3. Tighten inhibitor switch attaching bolts, then remove pin from adjusting hole.
4. Install and adjust control cable, then check continuity of inhibitor switch.