infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

Control Assembly, HVAC > < Condenser HVAC|Service and Repair|Page 7045
Page 3
background image

16. Pull condenser forward at an angle. Remove condenser from radiator.

CAUTION:  Be careful not to damage the core surface of condenser and radiator.

INSTALLATION

Installation is basically the reverse order of removal.

CAUTION:

-

Replace O-rings of high-pressure pipe 1 and high-pressure flexible hose with new ones, and then apply compressor oil to it when
installing it.

-

Female-side piping connection is thin and easy to deform. Slowly insert the male-side piping straight in axial direction.

-

Insert piping securely until a click is heard.

-

After piping connection is completed, pull male-side piping by hand to make sure that connection does not come loose.

-

When recharging refrigerant, check for leaks.

Control Assembly, HVAC > < Condenser HVAC|Service and Repair|Page 7045