Refrigerant Pressure Sensor / Switch: Description and Operation

REFRIGERANT PRESSURE SENSOR

Component Description

The refrigerant pressure sensor (1) is installed at the condenser of the air conditioner system. The sensor uses an electrostatic volume pressure transducer
to convert refrigerant pressure to voltage. The voltage signal is sent to ECM, and ECM controls cooling fan system.