M35x AWD V6-3.5L (VQ35DE) (2007)
^
Apply an axial load of 490 N (50 kg, 111 lb) to ball stud using a dial gauge. Measure amount of stud movement, and then make sure that the
value is within the following specified range. Replace outer socket and inner socket if the measured value is outside the standard.