infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2284 > < Initial Inspection and Diagnostic Overview|Page 2282
Page 170
background image

NOTE:
ECM and IPDM E/R have a termination circuit. Check other units first.
4. Connect the battery cable to the negative terminal. Check if the symptoms described in the "Symptom
(Results from interview with customer)" are reproduced.

NOTE:
Although unit-related error symptoms occur, do not confuse them with other symptoms.
Inspection result
Reproduced-Connect the connector. Check other units as per the above procedure.
Non-reproduced-Replace the unit whose connector was disconnected.

CAN System (Type 2)

CAN COMMUNICATION CIRCUIT

Diagnosis Procedure

1.CONNECTOR INSPECTION
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Disconnect all the unit connectors on CAN communication system.
4. Check terminals and connectors for damage, bend and loose connection.
Is the inspection result normal?
YES  - GO TO 2.
NO - Repair the terminal and connector.
2.CHECK HARNESS CONTINUITY (SHORT CIRCUIT)
Check the continuity between the data link connector terminals.

Is the inspection result normal?
YES  - GO TO 3.
NO - Check the harness and repair the root cause.
3.CHECK HARNESS CONTINUITY (SHORT CIRCUIT)
Check the continuity between the data link connector and the ground.

Is the inspection result normal?
YES  - GO TO 4.
NO - Check the harness and repair the root cause.
4.CHECK ECM AND IPDM E/R TERMINATION CIRCUIT
1. Remove the ECM and the IPDM E/R.

2. Check the resistance between the ECM terminals.

Initial Inspection and Diagnostic Overview|Page 2284 > < Initial Inspection and Diagnostic Overview|Page 2282