If the first three sets of numbers of the CONSULT-II Address match the IP Address on the ASIST PC (as noted in step 4C above)
proceed with step 41 below.

^

If the first three sets of numbers of the CONSULT-II Address do not match the IP Address on the ASIST PC proceed with step 4F
below.

F.

Touch the Address number on the CONSULT-II screen (titled "Configure Ethernet"). A numeric keypad will appear (see Figure 2c).

NOTE:

The IP Address for the ASIST PC you are working on will be different from the Address shown in Figure 2c.

G.

Use the key pad to set the CONSULT-II Address to match the ASIST PC IP Address with the exception that the CONSULT-II Address
number ends with 176.

H.

Touch [SAVE] and then press [COPY] to print the Address for future reference.

I.

Turn off CONSULT-II to allow the new Address to be saved in memory.

J.

On the ASIST PC close the "IP Configuration" window close the "MS-DOS Prompt" window then proceed with step 5 below.

DOWNLOAD (TRANSFER) DATA FROM ASIST INTO CONSULT-II