8. After the CONSULT-II displays "ADJUST THE VERTICAL OF LASER BEAM AIMING" turn the up-down direction adjusting screw until

"U/D CORRECT" value is set in the range of ?4.

CAUTION:  Turn the screw slowly. The value change on display is slower than actual movement of the ICC sensor integrated unit. Wait for 2
seconds
 every time the screw is turned half a rotation.

NOTE:  Turning the screw clockwise to laser beam is downward and counterclockwise to laser beam is upward.

9. When "U/D CORRECT" value indicates ±4, confirm that the margin of value remains within ?4 at least for 2 seconds with no equipment or hand

touching the ICC sensor integrated unit.

When "COMPLETED THE VERTICAL AIMING OF LASER BEAM" appears on screen, touch "END".

CAUTION:  Be sure that the margin of "U/D CORRECT" is within ?4 with ICC sensor integrated unit is untouched.

10. Confirm that "ADJUSTING AUTOMATIC HORIZONTAL LASER BEAM AIMING" is on screen and wait for a while (maximum: 10 seconds).