Battery Current Sensor: Description and Operation

BATTERY CURRENT SENSOR

Component Description

The power generation voltage variable control enables fuel consumption to be decreased by reducing the engine load which is caused by the power
generation of the generator. The battery current sensor (1) is installed to the battery cable at the negative terminal. The sensor measures the
charging/discharging current of the battery. Based on the sensor signal, ECM judges whether or not the power generation voltage variable control is
performed. When performing the power generation voltage variable control, ECM calculates the target power generation voltage based on the sensor
signal. And ECM sends the calculated value as the power generation command value to IPDM E/R. For the details of the power generation voltage
variable control, refer to Starting and Charging.

CAUTION:  Do not connect the electrical component or the ground wire directly to the battery terminal. The connection causes the malfunction of the
power generation voltage variable control, and then the battery discharge may occur.